128 Lice CT Scanner Systema Tomographiae Computatralis

1. Fames |
||
Apertura |
76CM |
|
Unus-button positio |
Praedefinitus 3 protocola |
|
Velocitas scannii\/360° |
0.48, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 2.0s |
|
Scannis FOV |
50cm |
|
Amplitudo inclinationis |
Inclinatio mechanica: ±30° (gradus 0.5°) |
|
Pannelum ostensionis |
Magnitudo: 13.3 pollices LCD, indicans parametra scansionis praesentis |
|
Vox automata |
Subsidium |
|
Interfacing cables ECG |
Integrata in fronte panelis controlis gantriae |
|
2. Lectus Patientis |
||
Max. ambitus itineris orizontalis |
1950mm |
|
Ambitus horizontalis scandendi |
50mm~ 1860mm |
|
Velocitas itineris horizontalis |
1~ 200mm/s |
|
Intervallum itineris tabulae verticalis |
425mm~990mm |
|
Maxima mensa onus |
250KG |
|
Unus-clavis tabulae patientis emissio |
Subsidium |
|
Commutatores culcitrae tabulae patientis |
Subsidium |
|
3. Tubus Radiographicus |
||
Capacitas Caloris Anodis |
5.3MHU |
|
Ratio refrigerandi |
815kHU/min |
|
Magnitudo Puncti Focalis |
Magna: 1.0mm X 1.0mm Parva: 0.5mm X 1.0mm |
|
4. Generator |
||
Virtus rating |
50.4kW |
|
configurationes kV |
70, 80, 100, 120, 140 kV |
|
intervalum mA (Magnitudo Gradus) |
10~420mA (gradus 1mA) |
|
5. Detector |
||
Materia |
Solidum GOS |
|
Numerus ordinum detectorum |
64 ordines |
|
Maximus numerus incisiorum / rotationem |
128 |
|
Numerus canalium detectorum per ordinem |
864 |
|
Totalis numerus elementorum detectorum |
55296 |
|
Min. crassitudo laminae |
0.625mm |
|
Latus detectoris |
40mm |
|
Max. ratio collationis data |
4800 views/360° |
|
6. Praestantia Scannandi |
||
Scan exploratorius |
Sustinet 3 modos: A.P. lateralem et duplem; Scannabilis ambitus 50~1860mm; |
|
Modi acquisitionis |
128 X 0.625mm 64 X 0.625mm 32 x 0.625mm |
|
Minima crassitudo slicii |
0.625mm |
|
Selectio latitudinis collimationis |
40mm, 20mm, 15mm, 10mm |
|
Factor pitch |
0.2~1.75 (plures selectiones) |
|
Max. tempus scandendi continuo |
100S |
|
7. Reconstructio Imaginis |
||
Recon FOV |
50~500mm; 50~650mm (Prolongatum) |
|
Matriculae recognitionis |
512X512, 768x 768, 1024X1024 |
|
Celeritas recognitionis |
≥40 folia per minutum, vera celeritas potest ad 42~28 folia per minutum pervenire |
|
Matricula ostensionis |
1024 X 1024 |
|
8. Algoritmus Optimationis Imaginis |
||
Reductio Artifactorum Metallicorum |
Standardus |
|
Reductio Artifactorum Indurationis Radii |
Standardus |
|
Reductio Artifactorum Voluminis Partialis |
Standardus |
|
Reductio artificiorum in steakage |
Standardus |
|
Reductio artificiorum in helicale scanning |
Standardus |
|
Reductio artificiorum motus |
Standardus |
|
9. Qualitas Imaginis |
||
Loci resolutio |
≥21 lp/cm @ 0% MTF; Planum X-Y ≥15 lp/cm@0% MTF; Planum Z |
|
Resolutio cum parvo contrastu |
[email protected]%@ 18mGy; |
|
Imaginis Strepitus |
≤0.35% (Dosis centralis≤40 mGy) |
|
CT HU scala |
Standardis: -1024HU ~ +3072HU Extensio: -32768HU ~ +32767HU |
|
10. Cardiacum Scans |
||
Prospectiva ECG scans |
Subsidium |
|
Retrospectiva ECG scans |
Subsidium |
|
Multi-sectorem coronarium arteriae scans |
Sectio self-adaptiva cum maxima supportio pro 4 sectis |
|
Resolutio Temporalis |
60ms; 25ms @ RTF |
|
Correctio undarum ECG |
Praebet functiones correctionis, addendae, et delendae pro ECG abnormibus (sicut praecox ictus) usata pro reconstructione arteriae coronariae |
|
Reconstructio cordis |
Automate optimitatem phase recon eligendi, multiphasicam reconstructionem pro tota sequentia vel singula imago |
|
Technologia praesentis coronariae artus congelationis RTF (Real Time Focus)
Algorismus tertius generationis correctionis motus artifacti basatus in profundo discentia potest simulare et compensare cor motus artifactum et partim eliminare defectus causatos ab insufficiente motu, respiratione et resolutione tempore. Dislocatio motus iteratur per methodum iterationis ut evitat nimiam correctionem.
|
||


Profilum Societatis
FAQ
1. Quid de niveau pretii? Confidimus nosmet ipsos quod praetia nostra sint competitiva comparata cum his eadem qualitas habentibus, quoniam plus quam viginti annis in hoc campo fuimus. Et semper adhaeremus principi ut optima qualitas productuum cum pretiis competitivis praestetur. Bonam famam nostram iam in multis regionibus constituimus, praesertim in Africa, Medio Oriente, Europa, Asia et America Meridionalis per annos multos laborem. 2. Cur invenimus alia pretia nimis alta esse comparata cum aliis venditoribus, et ex imagine aut numero modello, omnia eadem videntur? Quoniam Sinus adhuc est terra in progressu, pauci sunt producti cum iure patenti, et copia productorum cito diffunduntur in mercato. Certe, pretia earum copiarum cum materiis vilibus et minus qualitatis controlis relativè sunt viliora. 3. Quid de tempore tradendi? Cum producta nostra secundum singulas ordinationes specificas conficiantur, periodus tradendi erit dies 15 post confirmationem ordinis. Si parva vel ordo exemplariorum est, quaeso ut nos consulere de eo si habemus merces promptas in stock ut facere tradendum quam primum. 4. Quid de certamine qualitatis? Offertimus annum unum temporis garantiae incipiens ab tempore navandi pro instrumentis medicinis, Pro minimis problematibus, possumus praebere partes liberas in commutationem, Pro gravibus problematibus, possumus facere commutationem sine expensis. 5. Quae sunt conditiones praebendi pecuniam? T/T, Carta Crediti, L/C, Unio Occidentalis, PayPal, MoneyGram.