Accipe Citationem Gratuitam

Noster legatus tibi mox contactum faciet.
E-mail
Nōmen
Nōmen societātis
Nuntius
0/1000

Systema Radiographicum Fixum

Pagina Principalis >  Produse >  X-radii Solutio >  Systema Radiographicum Fixum

OMNIA PRODUCTA

Hospitale Medicum 630mA Digitalis Alta Frequentia Statuarium Diagnosticum Systema

  • Conspectus
  • Producta Commendata
Dēscrīptiō Prōductōrum
Hospitale Medicum 630mA Digitalis Alta Frequentia Statuarium Diagnosticum Systema
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System supplier
 Praecipua lineamenta: 1 Generator Frecuentiae Altae 1.1 Functiones: Radiographia digitalis, radiographia cum filtro, radiographia cum stante Bucky, ARP et AEC. 1.2 Potentia electrica nominalis: 50 kW 1.3 Voltium tubae: 40kV~150kV 1.4 Current tubae: 10mA~630mA 1.5 Tempus: 2ms~10s 1.6 mAs: 0.1mAs~630mAs 1.7 Freqventia operativa: ≥400kHz 1.8 Tabula controlis: LCD tactilis 2 Tubus X-ray 2.1 Max. Voltium tubae: 150kV 2.2 Focus: Parvus focus: 0.6mm; Magnus focus: 1.2mm 2.3 Potentia input anodis: parvus focus 19kW, magnus focus 50kW 2.4 Angulus target: 12° 2.5 Anodis RPM: 2800rpm 2.6 Capacitas caloris: 150kHU 3 Detector Tabulae Planae 3.1 GOS & Csl 3.2 Magnitudo: 35×43cm(14×17 unc.) 3.3 Pixel: 140μm 3.4 Matritia pixel: 2560×3072 3.5 Conversio A/D: 16Bit 4 Tabula Radiographica 4.1 Magnitudo: 2100mm×825mm×655mm (LxWxH) 4.2 Ambitus motus horizontalis: ≥250mm; 4.3 Ambitus motus longitudinalis: ≥825mm; 4.4 Locket tabulae summitatis: Locket electromagneticus, vis fricationis ≥100N, cum commutatore pedali, flexibilis et commodus. 4.5 Cum controlibus electricis vel manualem mechanicum motum, et functio alignamenti cum tubo X-ray et detector est automatica. 4.6 Magnitudo gridae: ≥15"×18"; Distantia focalis gridae: f0=100cm; Ratio gridae: r=10 :1; Densitas gridae: N=103Lineae/Inch 4.7 Columna Tubae 4.7.1 Structura secura et firma 4.7.2 Rotatio columnae: ≥±180° 4.7.3 Ambitus motus secundum tabulam: ≥1575mm, potest claudari in quocumque puncto 4.7.4 Motus tubae sursum et deorsum: 930mm±10mm, potest claudari in quocumque puncto 4.7.5 Rotatio tubae: ≥±180° 4.7.6 Max. Distantia a foco tubae ad filmam: ≥1200mm. 5 Stans Bucky 5.1 Ambitus motus sursum et deorsum: ≥1200mm; 5.2 In maxima altitudine, distantia inter pavimentum et centrum thecae est ≥1500 mm; 5.3 Magnitudo gridae: 18×18"; Focum gridae: f0=180cm; Ratio gridae: r=10 :1; Densitas gridae: N=103Lineae/Inch 6 Collimator: Flexibilis et commodus ad operationem, et omnis magnitudo campi radiographici rectanguli est disponibilis.
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System factory
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System supplier
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System supplier
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System factory
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System factory
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System supplier
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System supplier
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System details
Producta Relata
Responsa clientium
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System manufacture
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System supplier
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System manufacture
Officina
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System manufacture
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System factory
Profilum Societatis
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System manufacture
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System supplier
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System supplier
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System factory
FAQ
1. Quid de niveau pretii? Confidimus nosmet ipsos quod praetia nostra sint competitiva comparata cum his eadem qualitas habentibus, quoniam plus quam viginti annis in hoc campo fuimus. Et semper adhaeremus principi ut optima qualitas productuum cum pretiis competitivis praestetur. Bonam famam nostram iam in multis regionibus constituimus, praesertim in Africa, Medio Oriente, Europa, Asia et America Meridionalis per annos multos laborem. 2. Cur invenimus alia pretia nimis alta esse comparata cum aliis venditoribus, et ex imagine aut numero modello, omnia eadem videntur? Quoniam Sinus adhuc est terra in progressu, pauci sunt producti cum iure patenti, et copia productorum cito diffunduntur in mercato. Certe, pretia earum copiarum cum materiis vilibus et minus qualitatis controlis relativè sunt viliora. 3. Quid de tempore tradendi? Cum producta nostra secundum singulas ordinationes specificas conficiantur, periodus tradendi erit dies 15 post confirmationem ordinis. Si parva vel ordo exemplariorum est, quaeso ut nos consulere de eo si habemus merces promptas in stock ut facere tradendum quam primum. 4. Quid de certamine qualitatis? Offertimus annum unum temporis garantiae incipiens ab tempore navandi pro instrumentis medicinis, Pro minimis problematibus, possumus praebere partes liberas in commutationem, Pro gravibus problematibus, possumus facere commutationem sine expensis. 5. Quae sunt conditiones praebendi pecuniam? T/T, Carta Crediti, L/C, Unio Occidentalis, PayPal, MoneyGram.
Hospital Medical 630mA Digital High Frequency Stationary X-ray Diagnostic System details

Accipe Citationem Gratuitam

Noster legatus tibi mox contactum faciet.
E-mail
Nōmen
Nōmen societātis
Nuntius
0/1000