- Faahfaahin
- Bixiyo Oo La Sameeyo
HCX-50B Digital Mobile FPD C-arm Xogga X-ray (wajigi laaser ah) 

Isticmaalka:
La isticmaali dhow amaalka jajabka, degmada X-ray, guriga noocyada, shacabka iyo angiography biyaha dhexe.
Hanti guud, urology, hanti qolka, daawasho, hanti libin, hanti meelaha diblaha, hanti ganacsiga, isku daynta iyo ku xushinta dadhanka, endoscopy iyo hanti. Angiography iyo angioplasty diblaha diblaha.
Astaamaha Muhiimka ah:
1Ka mid ah abaadiyaha HF & HV, inverter, iyo image intensifier kama jirka ah, xubnaha x-ray wuxuu u shaqeyn karaa si toosan. Sidoo kale, waxaa ka dhacda dhaawacyada arrimo raad-radiyeed ee laabta.
2)Bordaha kontrollka LCD 10.4": fasilnimada shaqeynta, waxaana la weceli karaa 180° (L90°, R90°). Oo kuwa kale markii loo eego keyboard caadiga ah, tusaale bay display-ka LCD kuugu yar yahay in ay isku daydo. Sidoo kale, calaamadaha doonayaasha waxaa lagu muujin doonaa Sinis, taas oo kala saaran awoodda loo diiwaan gelin karo doonayaasha.
3)Fluoroscope pulse iyo boost ayaa siinaya qolooyinka macluumaadka xoog leh oo buuxda iyadoo la raacayo qolooyinka macluumaadka oo dhan.
4)Laanta guurxadda, wuxuu beddeli karaa maslulka si gaaban markuu soo galo. Sidoo kale, wuxuu leeyahay sifada nidaamka soo socota parallel.
5) Laanta geesaha block line, wuxuu idhiixda in kharash ah ka dhici doono markii markee soo socdo.
6) Gaarsiinta waaweyn ee aan la jarayn karin qodobka: gaarsiintu way gaadhilmaa 800mm, taas oo fududaysa shaqada.
7) Roolka saafidka khati ka Korean oo jawaan ayaa samayn karaa dhaawacyada bilowga mashinku si habboon u socda.
8) Loo isticmaalayo Relay Omron, waxaa laga saaro qalabka iyo wakhtiga shaqada ee xogga waxaa la badalaa.
Talabta ugu weyn
Jenerator HF |
120KV, 5kw ,40kHz |
|
Niqabka Fluoroscopy |
Habka fluoroscopy 40~120kv 0.5~5mA (KV xisaabta iyo xogga ah); Fluoroscopy dabool ah 40~120kv 0,5-5mA Fluoroscopy aalada leh 40~120kV 5~10mA; Fotograafi 40~120kV 1~250mAs |
|
X ray tube |
Focus labaad Midab jirta anode :0.3mm/0.6mm ,100mA Qodobka jirka :800KHU Italia IMD Teknoolojiyadda
|
Qalabka lagu ogaado |
Faransi Trixell Laf: A-Si TFT + photodiode plate lambar Scintillator: Csl Oryaha la guurayaa kasta oo ay ka bixiyeen: 1024 (1344 doorbixin) Joogga la guurayaa kasta oo ay ka bixiyeen: 1024 (1344 doorbixin) Dhexeeya pixel: 154 Ganacsiga quantization: 16 Kaydinta awoodda: 24 ±10% Xubnaha / guurka sawirka: Kabelka Ethernet |
|
Caqabadaha muhiimka ah ee kaashida waa: Halgan dabiici ah Si toos leh in lagu ilaaliyo dhalaalinta si toos leh ilaa 10 daqiiqo Awoodda in la saaro saynalka Fluoroscopy iyo RAD Qaab soo saarista barakhdhigga aan jirin carrabka Soo bandhigga sawirka badbaadka ugu fiican iyado la isticmaalayo xidha Ethernet |
|
Nidaamka xiriiraha |
5 Digri isku-dhufasho Dheeriska dhawr Qodob cad cadeynaha Ku jirin macluumaadka xiriira saacadaha Xiriirka ku jiran iyo istaagista Dhaxso dhawgalka oo ka mid ah xiriirka casriga ah S taageer “bashiiko kasto ” daabac, daabac warbixinta sawirka E saxiix Dicom 3.0 khat loo badalayo S taageerada fankaynta nidaamka Dicom 3.0 DAP (xogga ah ) |
|
Xogta faahfaahiinta mekanikaa (qaab elektrik u doorsho )
|
Socodka verticale: 0-400mm (koronto )Socodka horizontale: 0~200mm (qaab elektrik u doorsho) Isku-dhufasho ku dhisan meesha odaynaya: ±180° (qaab elektrik u doorsho) Socod buuxda arcar dhexe (qaab elektrik u doorsho) |
|
Dhamaan C-arm |
Dhererka goobta fookaska siidka: 1000mm Geesiga gacanta ≥650mm Jajabka noqon kara: 1800mm*800mm*1850mm Soo celinta image: 750mm*530mm*1680mm |
|
Dugsi Sare |
Qalabka lagu ogaado : 1 qayb saab x-ray: 1 qayb saxiix sawir 24lCD ekran kala duwan 1 kudhisa Xaaf xamar: 1 koox P dabiici: 1 kudhisa |
II Dugsi Sare
Maya. |
Tusmo |
Sharaxaad |
|
1 |
|
Waxaa la iibinayo geedaha HF & HV, inverter, geedaha x-ray wuxuu u shaqeyn karaa si toosan. Sidoo kale, waxay ku qaadaysaa dhaawacyada ee dhammaan dadka lagu dhaawacayo radiation.
|
|
2 |
|
10.4"LCD bogga kontrollaha hoose: shaqada wanaagsan waxaa loo rogo 180° (L90°,R90°) Marka la barbar dhigo keyboard caadi ah, shaashadeena LCD ma fududa in la marka lagu daro dhibaatada waxaa lagu soo bandhigi doonaa af ingiriisi taas oo hagaajin doonta waxtarka cudurka cillad la'aanta.
|
|
3 |
|
Iyada oo la adeegsanayo gacanta wadista, waxay hagaajin kartaa jihada si dhakhso ah marka ay dhaqaaqdo. sidoo kale waxaa la heli karaa shaqo dhaqdhaqaaq.
|
|
4 |
|
Waxaa lagu qalabeeyaa giraangiro gaar ah oo leh xariiqyo, waxay ka fogaan kartaa shilalka marka mashiinka uu dhaqaaqo.
|
|
5 |
|
Koreana salsal ah orijinilka ah salka salka ayaa samayn kartaa hadalka mashinku si habboon ugu socda.
|
6 |
|
La isticmaal Omron Relay , kalabka way ka yar karaa, waayo wakhtiga jirta xoogga ayaa si fiican ugu badanataa. |
7 |
Pulse iyo boost fluoroscope ay bixiyan jira eega si wanaagsan oo xaalad kasta oo weyn yar iyo weyn caawinaaya.
|
|
8 |
Guryo weyn hoose hor: gacantii waxa ku dhawaad 800mm ,taas oo fudud gargaarida aasaasiga ah. |
|
Sawirka Klinigka


ⅳ. Kala duwan
Muddooyinka: Laba xaalad: A) 252×93×174cm B) 90×80×140cm GW:500KG
Wakhtiga uga bixinta: ka dib marka hagaajis 15 maalmaha
Shuruudaha lacag bixinta: T/T
Wakhtiga garantiyada: kowggii
Habka soo saarka: Haddana ama badda