- Faahfaahin
- Bixiyo Oo La Sameeyo
Loo xiriira sano dhammaan tube X-ray:
• Hangzhou LR01 tube from China
• Tube IAE C339V ka soo jiray Italy
Saxda ah
1. Qalabka HM-9800D oo u dhawaaqda mamograafi molybdenum waa la tixgaliyey focus yar, habboon-tibaax, doosajiyada yar, iyo micro-computer ay ku daryeelaan.
2. Waa qalab ahaan u shaqaynta caafimaadka hoose loo eego taajida dhakarka dadweynaha iyo awood u leh in lagu arko dhakarka dadweynaha, node-ada, noqodhooyinka kalsiyam, iyo helitaanka dambegleynta ee jidh-xumo.
3. Nidaamka isticmaalka wixeynaysa leh oo leh panelka fidi-dheer, botanka gaarsiinta sare, iyo guurka qaldana.
4. Qaabka compressor saxsaneed ayaa sida sahlan u siinayaa sawirrada gacanta buuxda.
Meesha meesha kaarnonkii khaar ah oo kala duwan leh oo xargelinta X-ray yar taas oo sarrifka X-ray ka dhergata.
5. Qallooca 80KHz ee high frequency oo loo sameeyey teknoolojiga IGBT ee inverjonka high-frequency iyo teknoolojiga quasi-resonant pressure boosting.
wuxuu ugu leeyahay tijaabo, jiritaanka voltaajka, xariga tirada saxda ah oo abuura imiijiyada saaxiibsan.
diseenya mekaniika waxa kaa caawinaya:
Socod buuxda iyo qalad ah si toos ah iyo xooggan.
c-arm 360 wuxuu u haysta awood la socodka goobaha imiijiyada. 


Paramaamada Muuqashada
1. Jeneratori X-ray
Golaha Sare ee Qalbiya ah leh High-frequency High-voltage.
Nooca Geejinta: Inverter 80kHz ee Aragti Gaaban
Jiritaanka Gudaha: Khat 220VAC hal, 50/60Hz
Qiimaha Xoogga Radiographic: Qaybta weyn 20-35kV/10-510mAs
Qaybta yar 20-35kV/10-100mAs
Qiimaha Ammaanka: 6kW
2. Tubex X-ray
• Hangzhou LR01 tube from China
Saizenka Qaybta Focal: Focus Dual 0.2 / 0.4mm
Qaabka Laabka: Molybdenum (Mo)
Qaabka Port-ka: Beryllium (Be)
Qaadasho sare anode: 2800/1000rpm
Kuvarinta Target-ka: 12°/12°
Halgaga Anode Heat Storage: 100KJ (150kHU)
Xidhidda Anode: Xidhid ah
Filtration: Mo(0.03mm), Al(0.5mm)
• Tube IAE C339V ka soo jiray Italy
Caynaha Focal Spot: Dual Focus 0.1/0.3mm
Qaabka Laabka: Molybdenum (Mo)
Qaabka Port-ka: Beryllium (Be)
Qaadasho sare anode: 2800/1000rpm
Kuvarinta Target-ka: 10°/16°
Halgaga Anode Heat Storage: 210kJ (300kHU)
Xidhidda Anode: Xidhid ah
Filtration: Mo(0.03mm), Al(0.5mm)
3. Sandhiiska Radiography
C-ARM: Hantiidiinta Verticaal: 590mm
Qalbiga C-arm ku dhaqaaqaya kahraba, waayo qaladka dib u laabida wixii keyga ahaan
Dib u soo saara wixii dhisan inta loo dajiyey socodka in lagu dajiyo
Xuruufta xaqiiqsanaanta leh taranka taranka.
Salka ugu weyn: 200N
Tallaabka ugu sarreeya: 150mm
Iljisnimada Deg: +90°~-90°
SID: 650mm
4. Qoraalka Xisaabta Cassette
18*24cm (24cm*30cm go'ayn)
Qalabka Bucky: Mekanisimka Bucky ee 18*24cm, (24cm*30cm go'ayn)
Xaafadka Shabakadda: 5:1, 30 Khat/cm
5. Voltage carruurta
220Vac@25A, Fase eebe
6. Ciid iyo Saq
240kg (Waa Magac: 340kg)
L*W×H: 940mm*560mm*2000mm 