Product Introduction

1、The equipment is used for digital medical X-ray radiography of all parts of the whole body beside the patient bed through battery-assisted movement;
2、The equipment can be used in conjunction with a radiographic table and Bucky stand to perform digital medical X-ray radiography on the chest, abdomen, limbs, spine and other parts, which is convenient, fast, flexible and accurate;
3、The equipment can meet the needs of digital medical X-ray radiography in pediatric nursery boxes, emergency departments, ICU, orthopedics, operating rooms and other departments.

Configurations

No. Brand Model Product Name Quantity
1 - CELV-101C Flat Panel Detector 1
2 - FSQ-5-3M High Frequency Generator 1
3 Siemens SDR 150/30/50-1 X-Ray Tube 1
4 - XS-1 Collimator 1
5 - Angell-326-V Mobile Stand 1
6 - TS-5 DX Ray Diagnostic Workstation 1
* Microsoft Surface Go Tablet & Voice intercom & Remote visual monitoring system Optional


1. Flat Panel Detector

Detector Technology: Wireless a-Si Flat Panel Detector
Scintillator Material: CsI
Images Size: 350mm x 430mm(14"×17"inch)
Static Pixel Matrix: 2500 x 3052pixels
Effective Pixels: 7.63million
Pixel Size: 140μm
Spatial Resolution: 3.5lp/mm
Output Grayscale: 16bit
Image Preview Time: 2s (wireless) / 1s (wire)
Battery Standby Time: 10h
Connection: Wireless / Wire
Acquisition time: ≤7s
Power Supply: AC 100~240V, 50/60Hz, 20W
Resistant: IPX4
Dimensions: 383 x 460 x 15 mm
Weight: 3.3 kg
Operating Ambient Temperature: 10~40 °C
Operating Relative Humidity: 30~75 %

HFX-40D details

2.High Frequency Generator

High voltage generation method: high frequency inverter type
Nominal Output Power: 32kW
Maximum Output Power: ≥40kW
Maximum tube voltage: ≥150KV
Frequency: 50kHz/60kHz±1Hz
kV Range: 40-150kV, 1kV step
mA Range: 50-400mA
Maximum tube current: ≥400mA
mAs Range: 1-630mAs
Maximum tube current time product: ≥630mAs
Input power: AC 220V~230V~
With two-step exposure hand brake
With remote exposure control
With delayed exposure function
Three standard exposure configurations: wired, wireless, software solution
Support wireless transmission of images
DC exposure (Intelligent Dose Control)

HFX-40D manufacture

3.X-ray tube (Siemens SDR 150/30/50-1)

Focus: 0.6/1.0mm
Maximum Output Voltage: 150kV
Anode Heat Capacity: 330kHU
Anode Angle: 12°
Anode Rotating Speed: 10800rpm

3. Collimator

Control: Manual
Filter: 1.2mm Al
Light: LED lamp
Anti-collision rubber case
7-inch collimator operation information display screen
Laser ranging and SID displays

HFX-40D manufacture

5. Mobile Stand

Inductive battery-assisted drive design, linear and smooth movement, support one-hand drive
The Vertical Movement Range of X-ray Tube Center along the Column: 580-1800mm
Telescopic extension ranges from the center of the tube to the edge of the column: ≥450mm
The center of the tube rises and falls along the column: >1200mm
The Telescopic Movement Range of X-ray Tube Center along the Column Side: 720-1220mm
Stand Column Horizontal Rotation Range: ±315°
Collimator Rotation Range along the vertical axis: ±90°
Mobile Stand Size: 1230 × 580 × 1820 mm
Main body width: ≤580mm
Distance from the bottom edge to ground ≤60mm
Anti-collision features: collimator collision protection for human body, collision braking function for moving objects, anti-collision ultrasonic detection alarm
With power management system: low-power fast charging, intelligent management of power consumption, high-voltage generator sleeping, charging and power supply switch mode

HFX-40D factory

6. DX Ray Diagnostic Workstation & Image Processing Software

Display Size: 19inch
Pixel Matrix: 1280 x 1024pixels
Patient Management: Manual Registration, WORKLIST Automatic Query
Image Acquisition: Automatic Window Adjustment, Automatic Cropping, Automatic Transmission
Image Processing: Image correction, Image Flipping
Image Observation: Window Width/Level Adjustment, Image Flipping, Image Rotation, Image Scaling, and Restoration
Medical Record Report: Automatic Loading of Patient Information
Film Printing: Support DICOM3.0 Standard Laser Camera Printing
DICOM Transfer: Send images to any PACS and workstation that complies with the DICOM 3.0 standard
Real-time wireless transmission of images

HFX-40D details

7. Other features

Dose control mode
APR (Anatomically Programmed Radiography) mode
Manually setting the exposure mode
Mobility performance
Electrically assisted drive and has brake equipment
Support switch to manual mode without power
Slope assist system, maximum movement slope: ≤8°
Collision resistance
Collimator protector against human collision
Braking function for moving object collision
Interactive system
Time-lapse exposure function
Intercom system
Dual-screen display, 19-inch main control touch screen, 7-inch collimator operation information display screen
Remote visual observation system, Equipped with 10-inch tablet computer with remote visual monitoring system (Optional)
Innovative wireless visual exposure radiographic solution (Optional)
Innovative wireless voice intercom auxiliary guidance radiographic system outside the ward (Optional)
Power management system
Quick charging mode
Battery capacity ≥336V, 12Ah
Full battery life 30KM or 1200 exposures
Battery power display device
Independent control system for power assist and high frequency generator exposure output.
Power intelligent management system: computer sleep, high frequency generator sleep mode.
Intelligent power switching function: support exposure during charging.
Innovative standby sleep mode, the battery will automatically enter the sleep energy storage mode in the standby state, so that the standby time of the whole equipment is effectively extended by more than 30%.
Reliable and stable product performance and after-sales service advantages
Company Profile
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System factory
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System factory
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System manufacture
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System manufacture
FAQ
1. What about the price level? We are confident that our prices are competitive compared with those at the same quality level, since we have stayed in this filed more than 20 years. And we always adhere to the principle of provide top quality products with competitive prices. We have already established our good fame in many countries, especially in Africa, Middle East, European, Asia and South American through year after year efforts. 2. Why we find some prices are very high compared with some other supplier, and from the picture or it's model number, all looks the same? As China is still a developing country, there are only a few products with patent rights, and copy products I spread very fast in the market. Of course, the prices of those copy products with cheap material and less quality control are relatively cheaper. 3. What is time of delivery? Since our products are produced according to each specific order, the delivery period will be 15 days after confirmation of order. If it is small or sample order, please do check with us about whether we have ready goods in stock to make delivery as soon as possible. 4. What about quality assurance? We offer one year warranty period beginning from the time of shipment for medical equipment, Per minor problems, we can provide free spare parts for replacements, Per serious problems, we can make replacement of free charge. 5. What is payment terms? T/T, Credit Card, L/C, Western Union, PayPal, MoneyGram.
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System details
Recommended Products

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000