Zatražite besplatnu ponudu

Naš predstavnik će vas uskoro kontaktirati.
E-mail
Ime
Naziv tvrtke
Poruka
0/1000

SVE PROIZVODA

Profesionalna bolnička uporaba molibdenski cilj mamografija R-rentgen stroj za dijagnostičko ispitivanje dojica

  • Pregled
  • Preporučeni proizvodi
Opis proizvoda
Molibdenov cilj mamografskog rentgena za dijagnostičko ispitivanje dojica
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination details
Dva različita rentgenska cijevi za izbor: • Cijev Hangzhou LR01 iz Kine • Cijev IAE C339V iz Italije Značajke 1. Mamograf s visokofrekventnim molibdenovim ciljem HM-9800D karakteriziran je vrlo malim fokusom, visokom rezolucijom, niskom dozom i mikroračunalnim upravljanjem. 2. To je visoko performantni uređaj za ispitivanje dojica s visokom osjetljivošću za lijepe tumoritve, čvrste čvorove, kalcifikirane točke i rano otkrivanje zlobnih tumoritve. 3. Jednostavno korisničko sučelje s dodirnim panelom, brzo dostupnim tipkama i stopačkim prekidačem. 4. Strujast kompresorski ploča omogućuje cjelovite slike dojice. Kvalitetna ugljenovodika stolica s niskom X-zracnom absorpcijom koja smanjuje rasutne X-zrake. 5. Generatorski sustav frekvencije od 80KHz dizajniran je s naprednom IGBT visokofrekventnom inverzijom i kvazi-rezonantnom tehnologijom povišenja tlaka. 6. Obezbeđuje visoku učinkovitost, stabilno napon, čisti izlazni spektralni red koji proizvodi visoko definirane slike. 7. Povjerljiva i trajna mehanička konstrukcija pruža: Električno gornje/dolje pomično glatko i tiho. Slobodno rotirajući C-arm od 360 stupnjeva pruža slikarsku fleksibilnost. Glavni parametri 1. Generator za X-zrake Potpuni generator visokog frekvencijskog napona s visokim tlakom na temelju čvrstog stanja. Vrsta generatora: Inverter visoke frekvencije 80kHz Ulazna snaga: Jednofazni 220VAC, 50/60Hz Rejting za rentgen: Veliki fokusni točak 20-35kV/10-510mAs Mali fokusni točak 20-35kV/10-100mAs Snaga: 6kW 2. Zraka cijevi • Cijev Hangzhou LR01 iz Kine Veličina fokalne točke: Dvostruki fokus 0.2 / 0.4mm Matrijal cilja: Molibden (Mo) Matrijal porta: Berilij (Be) Brzinsko vođenje anoda: 2800/1000rpm Ugao cilja: 12°/12° Spremanje topline anode: 100KJ (150kHU) Hlađenje anode: Zrakohlađenje Filtracija: Mo(0.03mm), Al(0.5mm) • IAE C339V cijev iz Italije Veličina fokalne točke: Dvostruki fokus 0.1/0.3mm Matrijal cilja: Molibden (Mo) Matrijal porta: Berilij (Be) Brzinsko vođenje anoda: 2800/1000rpm Ugao cilja: 10°/16° Spremanje topline anode: 210kJ (300kHU) Hlađenje anode: Zrakohlađenje Filtracija: Mo(0.03mm), Al(0.5mm) 3. Radiografska postaja C-RAK: Vertikalno pomjeranje: 590mm Centar električnog rotacijskog C-raka, funkcija automatskoga povratka jednim tipkom Automatski otpuštan nakon postavki tlaka izloženja prikaza Tlak: 200N Maksimalni put: 150mm Rotacije: +90°~-90° SID: 650mm 4. Kasetni prijemnik slike 18*24cm (opcionalno 24cm*30cm) Bucky uređaj: 18*24cm Bucky mehanizam vođenja, (opcionalno 24cm*30cm) Omjer rešetke: 5:1, 30 Linija/cm 5. Napona linije 220Vac@25A, jedna faza 6. Težina i veličina 240kg (Ukupna težina: 340kg) D*Š×V: 940mm*560mm*2000mm
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination supplier
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination manufacture
Vrsta generatora
Visokofrekvencijski inverter 80kHz
Oznaka snage
6Kw
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination details
Radionica
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination manufacture
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination manufacture
Povratne informacije kupaca
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination manufacture
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination details
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination factory
Profil tvrtke
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination supplier
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination details
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination factory
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination details
Česta pitanja
1. Kako stoji s razinom cijene? Sigurni smo da su naši cijenici konkuretni u usporedbi s cijenicama iste kvalitete, jer smo bili aktivni u ovom sektoru više od 20 godina. Uvijek pridržavamo se principa pružanja proizvoda najbolje kvalitete po konkurentnim cijenama. Već smo stvorili dobro ime u mnogim zemljama, posebno u Africi, Bliskom Istoku, Europi, Aziji i Južnoj Americi nakon godinama truda. 2. Zašto nam neki cijenici izgledaju vrlo visoki u usporedbi s nekim drugim dobavljačima, a slično izgleda i slike ili modelni broj? Kako je Kina još uvijek u razvoju, postoje samo nekoliko proizvoda s patentom, a kopirani proizvodi se brzo šire na tržištu. Naravno, cijenici tih kopiranih proizvoda s jeftinim materijalima i manje kontrolom kvalitete su relativno niže. 3. Što je vrijeme isporuke? Kako naše proizvode proizvodimo prema svakoj specifičnoj narudžbi, rok isporuke će biti 15 dana nakon potvrde narudžbe. Ako je malena ili probna narudžba, molimo vas da s nama provjerite imamo li gotovu robe na zalihi za što bržu isporuku. 4. Što se tiče jamstvenog osiguranja? Nudimo jednogodišnji period jamstva počevši od vremena otpreme medicinskog opreme. Za manje probleme, možemo pružiti besplatne rezervne dijelove za zamjenu. Za ozbiljnije probleme, možemo izvršiti besplatnu zamjenu. 5. Koji su uvjeti plaćanja? T/T, Kreditna kartica, L/C, Western Union, PayPal, MoneyGram.
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination manufacture

Zatražite besplatnu ponudu

Naš predstavnik će vas uskoro kontaktirati.
E-mail
Ime
Naziv tvrtke
Poruka
0/1000