Accipe Citationem Gratuitam

Noster legatus tibi mox contactum faciet.
E-mail
Nōmen
Nōmen societātis
Nuntius
0/1000

OMNIA PRODUCTA

Systema Digitalis Mammographicum

  • Conspectus
  • Producta Commendata
Dēscrīptiō Prōductōrum
Hdacddf1b89.jpgHc36286546e.jpg

Technica  Specificatio

Non. Elementum Specificatio
1 X-ray generans
1.1 Definition Generator solidus totus alti-frquentiae et alti-voltage.
1.2 Genus Generatoris Inversor Altius Freqentiae 80kHz
1.3 Potentia Input Fase Singula 220VAC, 50/60Hz
Magnus Punctum Focale 20-35kV/10-510mAs
1.4 Cursus Radiographici Parvus Punctum Focale 20-35kV/10-100mAs
1.5 Virtus rating 6.2kW
2 Tubus Radiologicus
2.1 Model IAE C339V
2.2 Magnitudo Puncti Focalis Focus Dualis 0,1/0,3mm
2.3 Materies Obiecti Molybdochalcum (Mo)
2.4 Porta Materialis Berillium (Be)
2.5 Rapida Motus Anodi 3000/10000 rpm
2.6 Angulus scopi 10°/15°
2.7 Caloris Stocagium Anodae 225KJ (300KHU)
2.8 Refrix Anodae Air refrigerationem
2.9 Filtratio Mo(0,03mm)
3 Radiographicus Statuens
3.1 Motus Verticalis Brachii U 560mm
3.2 Rotatio Brachii U Functio redditionis automaticae per unum clavem
3.3 Rotationes Graduum +90°~-90°
3.4 Compressor Compressor postquam expulsio completa est automatice resolvitur
3.5 Pressio Maxima Compressoris 200N
3.6 Iter Maximum Compressoris 156mm
3.7 SID 650mm
4 Detector
4.1 Materies Detectoris Silicium amorphum
4.2 Cobertura Efficax Detectoris 24cm×30cm
4.3 Matrice Pixellarum 2816×3528
4.4 Limes Resolutionis Spatialis 6.0Lp/mm
4.5 Valor DQE @4 Lp/mm:≥35%
4.6 Dynamic range productus Digitalis 14bit
4.7 Pixel magnitudine 85μm
4.8 Productio Ethernet
4.9 Operantes conditio 10℃-40℃
4.1 Repono Environment -10℃-50℃
5 Instrumenta ad Capta Imaginum
5.1 CPU Intel Core Duo 3.0GHz
5.2 Ferramenta ≥1T Instrumenta Velocitatis Elevatae
5.3 Memoria ≥8G
5.4 Charta Display ≥2G
5.5 LCD Altae Luminositatis et Altioris Contracti 1920*1080 Pixel ReSolutionis
5.6 Interface Rete cum Indice Operum Transmissio DICOM3.0
ethernet Gigabit 100/1000
5.7 Software Pacquetum Software Imaginis DMOC V1.0
6 Voltus Lineae 220VAC@15A, Fase Singula
7 Pondus sarcinae 469kg
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination details
Responsa clientium
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination manufacture
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination details
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination factory
Profilum Societatis
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination supplier
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination details
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination factory
Professional Hospital Use  Molybdenum Target Mammography X-ray Machine for Breast Diagnostic Examination details
FAQ
1. Quid de niveau pretii? Confidimus nosmet ipsos quod praetia nostra sint competitiva comparata cum his eadem qualitas habentibus, quoniam plus quam viginti annis in hoc campo fuimus. Et semper adhaeremus principi ut optima qualitas productuum cum pretiis competitivis praestetur. Bonam famam nostram iam in multis regionibus constituimus, praesertim in Africa, Medio Oriente, Europa, Asia et America Meridionalis per annos multos laborem. 2. Cur invenimus alia pretia nimis alta esse comparata cum aliis venditoribus, et ex imagine aut numero modello, omnia eadem videntur? Quoniam Sinus adhuc est terra in progressu, pauci sunt producti cum iure patenti, et copia productorum cito diffunduntur in mercato. Certe, pretia earum copiarum cum materiis vilibus et minus qualitatis controlis relativè sunt viliora. 3. Quid de tempore tradendi? Cum producta nostra secundum singulas ordinationes specificas conficiantur, periodus tradendi erit dies 15 post confirmationem ordinis. Si parva vel ordo exemplariorum est, quaeso ut nos consulere de eo si habemus merces promptas in stock ut facere tradendum quam primum. 4. Quid de certamine qualitatis? Offertimus annum unum temporis garantiae incipiens ab tempore navandi pro instrumentis medicinis, Pro minimis problematibus, possumus praebere partes liberas in commutationem, Pro gravibus problematibus, possumus facere commutationem sine expensis. 5. Quae sunt conditiones praebendi pecuniam? T/T, Carta Crediti, L/C, Unio Occidentalis, PayPal, MoneyGram.