INDEX PRAECIPIENDORUM HDR-580

Detector Detector Planus Dynamicus 1 /
Statio Diagnostica DXRay 1 /
Systema Radiographicum Generator Altus Frequentia 1 /
Imperium consolatorium 1 /
Tubus Radiologicus 1 /
Cavi Altivoltales 2 /
Collimator 1 /
Systema Controllis Motus Stativum Brachii UC 1 /
Lectulus photographicus mobilis 1 /
Platform 1 /
Accesoria Eget 1 /
Impressor Laser Rerum Gestarum 1 /
Microphonium/Altophonium 1 /


HDR-580 SPECIFICATIONES

Detector Planus Dynamicus Typus Detectorem Plani Dynamicum detector Planus a-Si
Typus Laminae Scintillationis CsI (Iodidum Caesii)
Campus Visionis Efficax 17 × 17 in. (43 × 43 cm)
Matrix Pixel Statica 3072 × 3072
Matrix Pixel Dynamicus 1536x 1536
Matrix Pixelis Radiographica 3072x 3072
Pixel magnitudine 140μm
Tempus Praeparationis Radiographiae ≤0.8s
Output in grisescales 16bit
Tempus acquisitionis ≤5S
Tempus Imaginis Praeviae ≤3s
Maxima Resolutio Spatialis 3.5Lp/mm
Intervalum Motus Detectroris 0 - 1000mm
Tubus Radiologicus Foculus tubi 0.6mm/1.0mm
Maxima Tensio Egressus 150kV
Calorem facultatem 330kHU
Velocitas Anodi Rotantis 9000r/min
Potentia output 30kW/50kW
Generator Requisitum Potentiae 380V cum Tribus Fasis
Maximum output Power 50kW
Tensio Egressus pro Radiographia 40kV-150kV
Tensio Egressus pro Fluoroscopia 40kV-120kV
Currentis Exsulans pro Radiographia 10-650mA
Currentis Exsulans pro Fluoroscopia 0.5-6mA
Ammannus mAs 0.4mAs-630mAs
Brachium UC Functio Electio Automatice Luciditatis (ABS) -
Unius Clavis Positioning pro Exam Thoracis/Exam Tabulae per Controllum Electricum. -
FID 465~1700 mm
SID 1000~1800 mm
Amplitudo rotationis brachii UC -30°~+120°
Amplitudo rotationis detectoris -30°~+30°
Longitudo catenarum alti voltatus 8M
Magnitudo tabulae radiographicae (optio) 2000 mm × 820 mm × 750 mm (quattuor fluitantes)
Magnitudo tabulae radiographicae (SC-1) 2000 mm × 650 mm × 760 mm
Eget Densus reticuli 40lp/cm
Rationem rastri 10:01
Focus 100cm
Collimator Maxima Dosis Laboris 150kVp
Potentia 150W(24VAC)
Tempus Automatice Claudendi 30s
Claritas ≥160lux(100cm)
Statio Lavoris (possibilitas adaptationis) CPU I5
RAM 4GB
Cardina Retei Communicationis 1000m
Discus durus 500g
Display 1280*1024
CD/DVD registri et comburendi -
Software - Indicatore Partis Imaginis, Aequalizatio Textus, Correctio Filtri, Transformatio Grayscale, Regulatio Fenestra/Nivellus, Correctio Gamma, Aequalizatio ROI
- Reversio Nigra/Alba, Segmentatio Imaginis, Nota, Potentiatio, Lenimentum
- Acuendo, Compressio, Magnificatio, Rationes Graphicae cum Textu, Imprimere
- Imprimere in Pellicula, Suadet Standardi DICOM 3.0, Impressor Pellicularis Laser
- Forma DICOM 3.0, Compatibilis ad Transferendum ad PACS


HDR-580 est prima UC-ARM dynamica DR in mundo cum detectore planopanellensi novissimi generis. Eius functiones multae, structura mechanica ingeniose excogitata et operatio facilis efficiunt perfectissimum systema DR et optimam solutionem sectionis examinationis physicae quae plerosque examinandi radiographici fereat, ut columna cervicalis, columna lumbalis, angiographia esophagea, simulque frueris innovationibus nostris in studiis et developmente. Fructare installata basi plus quam 3000 unitatum dynamicae DR.

Cursus Examinationis Celeris Unico Impetu
Hoc adhiberi potest ad sanitatis inspectio unico loco pro pectore, vertebra cervicali, vertebra lumbali et fluoroscopia sine apparatu supplementario. Hoc instrumentum plerumque examinationes radiographica perficere potest, quae facile et commodissime operari possunt.

Tempus examinationis minuere, et efficentiam augere
Patiens celeriter pleraque examinatio radiographica facere potest, sine ambulando per varios sectiones examinationis. Hoc tempus inspectionis medicae et tempus expectandi patientis magno modo reducere potest, et efficentiam sectionis examinationis physici, quae centenas patientium quotidie examinat, meliorem efficit.

Magnae pecuniae conservationes cum paucioribus ministerialibus in paucioribus cellis
Solutio omnia in uno complectitur varios examinandi radios X, a studiis fluoroscopiae ad imaginem radiographicam altioris definitionis, quae significanter spatium conservat per reductionem locorum et auxit flexibilitatem in sectione examinationis physicae per reductionem personarum opus habentium ad operandum. Hospitale magnas impensas laboris et loci effugit.

Systema Altum Rendimentum

Experientia Usoris Satisfaciens
Observatio realis temporis de toto contractu, una imago ostendit omnes particulas.

Radiogrāphia digitālis
Latissimo ambitu angulorum examinationis, necnon positionibus erectis, iacentibus et obliquis. Cranium, Thorax, Abdomen, Columna vertebralis, Pelvis, Extremitates superiores et inferiores et cetera.

Fluoroscōpia digitālis
Imagines dynamicae pro fluoroscopia, observatione ac localisatione lesionis, et pellicula puncti altius resolutionis, oesophagographia, urographia intravenosa (IVP), HSG, colangiographia tubo T et cetera.

Prūdēns coaptātiō imāginis
Cum evolutionato statio elaborationis imaginum, Angell systema dynamicum DR imministrare potest imaginem definitionis altissimae a capite usque ad calcaneum, praesertim utilis pro orthopaedia.

Technologia FPD dynamica novissima pro R&F

Detector planus dynamicus Angell, cuius area imaginum est 430mm × 430mm, destinatur ad usum in radiographia generali et fluoroscopia (R&F). Offert absorptionem X-radiationis insignem, minuendo expositionem patientis dum qualitas imaginis praestantissima servatur.

Hic detector peritiam nostram profundam in technologiis medicis demonstrat. Coniungit altam efficientiam quanti detectionis (DQE) cum multitudine magnae pixelarum et alto ambitu dynamico (16 bit), ostendens etiam minimas differentias ad diagnosticum altissimae praecisionis. Tuis utere innovationibus nostris in studiis et developmente.

Excellens Systema Elaborationis Imaginum

praeditus progresso software pro elaboratione imaginum ad meliorem qualitatem imaginis. Innovativa praestantia pro melioratione imaginum auxilium praebeat, ut plura discrimina videas, fiduciamque maiorem habeas in tua diagnose.

Efficientia Intelligentis Automatice Enhancement
iEAE multum auxilium tulit ad constantiam, mollitiem, gradationem spatialem et tenuitatem texturae imaginis.

iDG
Intelligentes DeGrid
iDG intellegenter agnoscit artefacta gredioli, ut effectus imaginis eximius servetur.

iMR
Intellegens Metalli Recognitio
iMR potest intellegenter analysare et agnoscere regiones metallicas in imagine, easque tractare per specialem elaborationem imaginis, ut vitetur artefactum circa metallum et diagnosim falsam.

iGCR
Intelligentis Grisii Compensatio Regionis Obiectivae
iGCR potest agnoscere aream expositionis effectivam et griseum regionis compensare. Ad augendam imaginem crudi processum sub diversis parametris expositionis et ad conservandum qualitatem imaginis in altiori nive.

h5.jpgh6.jpg

Profilum Societatis
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System factory
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System factory
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System manufacture
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System manufacture
FAQ
1. Quid de niveau pretii? Confidimus nosmet ipsos quod praetia nostra sint competitiva comparata cum his eadem qualitas habentibus, quoniam plus quam viginti annis in hoc campo fuimus. Et semper adhaeremus principi ut optima qualitas productuum cum pretiis competitivis praestetur. Bonam famam nostram iam in multis regionibus constituimus, praesertim in Africa, Medio Oriente, Europa, Asia et America Meridionalis per annos multos laborem. 2. Cur invenimus alia pretia nimis alta esse comparata cum aliis venditoribus, et ex imagine aut numero modello, omnia eadem videntur? Quoniam Sinus adhuc est terra in progressu, pauci sunt producti cum iure patenti, et copia productorum cito diffunduntur in mercato. Certe, pretia earum copiarum cum materiis vilibus et minus qualitatis controlis relativè sunt viliora. 3. Quid de tempore tradendi? Cum producta nostra secundum singulas ordinationes specificas conficiantur, periodus tradendi erit dies 15 post confirmationem ordinis. Si parva vel ordo exemplariorum est, quaeso ut nos consulere de eo si habemus merces promptas in stock ut facere tradendum quam primum. 4. Quid de certamine qualitatis? Offertimus annum unum temporis garantiae incipiens ab tempore navandi pro instrumentis medicinis, Pro minimis problematibus, possumus praebere partes liberas in commutationem, Pro gravibus problematibus, possumus facere commutationem sine expensis. 5. Quae sunt conditiones praebendi pecuniam? T/T, Carta Crediti, L/C, Unio Occidentalis, PayPal, MoneyGram.
Hospital High End 1.5T  MRI Scanner Machine Magnetic Resonance Imaging System details

Accipe Citationem Gratuitam

Noster legatus tibi mox contactum faciet.
E-mail
Nōmen
Nōmen societātis
Nuntius
0/1000