Insitum 568 CT

  • Conspectus
  • Producta Commendata
Dēscrīptiō Prōductōrum
Gantry

Apertura 76CM
Unus-button positio Praedefinitus 3 protocola
Velocitas scannii\/360° 0,48; 0,5; 0,6; 0,7; 0,8; 0,9; 1,0; 2,0 s
Scannis FOV 50cm
Amplitudo inclinationis Inclinatio mechanica: ±30° (gradus 0.5°)
pannelum ostensionis Magnitudo: 13.3 pollices LCD, indicans parametra scansionis praesentis
Vox automata Subsidium
Interfacing cables ECG Integrata in fronte panelis controlis gantriae

Patientis Mensa

Max. ambitus itineris orizontalis 1950mm
Ambitus horizontalis scandendi 50 mm ~ 1860 mm
Velocitas itineris horizontalis 1 ~ 200 mm/s
Intervallum itineris tabulae verticalis 425mm~990mm
Maxima mensa onus 250KG
Unus-clavis tabulae patientis emissio Subsidium
Commutatores culcitrae tabulae patientis Subsidium

Tubus Radiologicus

Capacitas Caloris Anodis 5.3MHU
Ratio refrigerandi 815kHU/min
Magnitudo Puncti Focalis Maior: 1,0 mm × 1,0 mm
Minor: 0,5 mm × 1,0 mm

Generator

Virtus rating 50.4kW
configurationes kV 70, 80, 100, 120, 140 kV
intervalum mA (Magnitudo Gradus) 10 ~ 420 mA (gradus 1 mA)

Detector

Materia Solidum GOS
Numerus ordinum detectorum 64 ordines
Maximus numerus incisiorum / rotationem 128
Numerus canalium detectorum per ordinem 864
Totalis numerus elementorum detectorum 55296
Min. crassitudo laminae 0.625mm
Latus detectoris 40mm
Max. ratio collationis data 4800 views/360°

Prestatio Scansionis

Scan exploratorius Tres modos sustinet: lateralem A.P. et duplex;
Intervallo scandendi 50~1860mm;
Modi acquisitionis 128 x 0,625mm
64 x 0,625mm
32 x 0.625mm
Minima crassitudo slicii 0.625mm
Selectio latitudinis collimationis 40mm, 20mm, 15mm, 10mm
Factor pitch 0.2~1.75
(selectio multiplex)
Max. tempus scandendi continuo 100S

imaginis Reconstruendae

Recon FOV 50~500mm;
50~650mm (Extensum) •
Matriculae recognitionis 512×512、768×768、1024×1024
Celeritas recognitionis ≥40 ips, 42~28 ips
Matricula ostensionis 1024×1024

algorithmus Optimizandi Imaginis

Reductio Artifactorum Metallicorum Standardus
Reductio Artifactorum Indurationis Radii Standardus
Reductio Artifactorum Voluminis Partialis Standardus
Reductio artificiorum in steakage Standardus
Reductio artificiorum in helicale scanning Standardus
Reductio artificiorum motus Standardus

Qualitas Imaginis

Resolutio spatialis: ≥21 lp/cm @ 0% MTF; in plano X-Y
≥15 lp/cm @ 0% MTF; in plano Z
Resolutio cum parvo contrastu [email protected]%@ 18mGy;
Imaginis Strepitus ≤0.35% (Dosis centralis≤40 mGy)
CT HU scala Standard: -1024HU ~ +3072HU
Amplificatum: -32768HU ~ +32767HU

Computra systema

CPU Intel Xeon 6 nucleus, 12 fili, frequentia 3.8 GHz, cache 8.25MB
RAM ECC 32 GB
Discus durus 7TB (discus systematis 0.3 TB + discus imaginum 1.7TB + discus datorum cruddorum 5 TB)
Monitor Magnitudo: 24 pollices, LCD
Resolutio: 1920×1200
Luminositas: 600cd/m²
Contrastus: 1000:1
Imaginum condensatio ≥3.200.000 imagines (512×512)
Condensatio externa DVD/CD RW, USB
Interface impressionis Norma DICOM 3.0

Optimizatio dosis

Protocolla pediatrica dedicata Standardus
Auto-mA Standardus
V-Dose check Standardus
Imago pulmonis ad dosim minutam Standardus
expositio 240° Standardus
V-Beam Standardus
Rapportum V-Dose Standardus
reconstructio iterativa iDream Standardus
V-Bolus tracking Standardus
Temporizatio V-Bolus Standardus
Modulatio mA ECG Standardus
Scanning cardiacum

Prospectiva ECG scans Subsidium
Retrospectiva ECG scans Subsidium
Multi-sectorem coronarium arteriae scans Sectio self-adaptiva cum maxima supportio pro 4 sectis
Resolutio Temporalis 60ms;
25ms @ RTF
Correctio undarum ECG Praebet functiones correctionis, addendae, et delendae pro ECG abnormibus (sicut praecox ictus) usata pro reconstructione arteriae coronariae
Reconstructio cordis Automate optimitatem phase recon eligendi, multiphasicam reconstructionem pro tota sequentia vel singula imago


Technologia instantanea congelandi arteriarum coronariarum RTF (Real Time Focus). Tertium genus algorithmi correctionis artifacti motus ex doctrina profunda petitum corripiet et compensabit artifacta motus, respirationis et resolutionis temporalis insufficientis. Motus displacement iterata correctione corrigitur ne corrigatur nimis.

Applicatio Clinica

Insitum 568 CT manufacture

Accesoria
Latin accessiones
Insitum 568 CT manufacture

ACCESSORIA OPTIONALIA

Insitum 568 CT supplier

Condicio Operativa et Requisita Locata
Mensurae & Pondus

Systema Longitudo Latitudo Altitudo Pondus
Gantry 2200 mm 1021 mm 1969 mm 1800 Kg
Mensa 680 mm 2678 mm 1073 mm 450 Kg
Console 450 mm 716 mm 652 mm 60 kg
Distributorem 800 mm 430 mm 663 mm 170 kg

Requisita Locandi (Praecepta)

Insitum 568 CT details

Condicio Operativa

Dimensio Cubiculi Scandendi Area minima: 22,4 m² (5600 mm x 4000 mm)
Magnitudo praecipua cubiculi: 30 m² (6000 mm x 5000 mm)
Dimensio Cubiculi Operandi Magnitudo praecipua cubiculi: 3000 mm x 5000 mm x 2800 mm
Temperatura et Humiditas Temperatura: cubiculus scandendi: 20–26 ℃;
cubiculus operandi: 18–28 ℃
Humiditas: camera scandendi: 30%~70%, nullum condensatum;
camera operandi: 20%~80%, nullum condensatum
Postulata de potentia electrica Capacitas electrica: 70kVA
Optio copiae electricae: tribus phasibus 380 VAC, variatio voltaginis: tolerantia ≤±10%
Frequentia: 50 Hz vel 60 Hz, tolerantia ≤±1 Hz
Economia intelligentis energiae Scandentes CT seriei Insitum ita sunt constructi ut energiam conservent, et modus stand-by ulterius est optimizatus, quo fit ut dispositiva pressionis altioris regulentur et data colligantur in operatione viva minuantur. Sola componentia necessaria manent in statu laborandi. Haec ratio efficienciam initiandi normalem non afficit, dum consumptio anni electricitatis diebus 10 horarum per diem, sex diebus per hebdomadam, minuitur per 2815 kW·h, quod est 62,5% minus quam in priore constructione.


Ophthalmic Touch Screen Automatic Optical Coherence Tomography OCT Scanner Machine factory

Responsa clientium
Ophthalmic Touch Screen Automatic Optical Coherence Tomography OCT Scanner Machine details
Ophthalmic Touch Screen Automatic Optical Coherence Tomography OCT Scanner Machine factory
Producta Relata
Profilum Societatis
Ophthalmic Touch Screen Automatic Optical Coherence Tomography OCT Scanner Machine factory
Ophthalmic Touch Screen Automatic Optical Coherence Tomography OCT Scanner Machine manufacture
Ophthalmic Touch Screen Automatic Optical Coherence Tomography OCT Scanner Machine manufacture
Ophthalmic Touch Screen Automatic Optical Coherence Tomography OCT Scanner Machine supplier
FAQ
1. Quid de niveau pretii? Confidimus nosmet ipsos quod praetia nostra sint competitiva comparata cum his eadem qualitas habentibus, quoniam plus quam viginti annis in hoc campo fuimus. Et semper adhaeremus principi ut optima qualitas productuum cum pretiis competitivis praestetur. Bonam famam nostram iam in multis regionibus constituimus, praesertim in Africa, Medio Oriente, Europa, Asia et America Meridionalis per annos multos laborem. 2. Cur invenimus alia pretia nimis alta esse comparata cum aliis venditoribus, et ex imagine aut numero modello, omnia eadem videntur? Quoniam Sinus adhuc est terra in progressu, pauci sunt producti cum iure patenti, et copia productorum cito diffunduntur in mercato. Certe, pretia earum copiarum cum materiis vilibus et minus qualitatis controlis relativè sunt viliora. 3. Quid de tempore tradendi? Cum producta nostra secundum singulas ordinationes specificas conficiantur, periodus tradendi erit dies 15 post confirmationem ordinis. Si parva vel ordo exemplariorum est, quaeso ut nos consulere de eo si habemus merces promptas in stock ut facere tradendum quam primum. 4. Quid de certamine qualitatis? Offertimus annum unum temporis garantiae incipiens ab tempore navandi pro instrumentis medicinis, Pro minimis problematibus, possumus praebere partes liberas in commutationem, Pro gravibus problematibus, possumus facere commutationem sine expensis. 5. Quae sunt conditiones praebendi pecuniam? T/T, Carta Crediti, L/C, Unio Occidentalis, PayPal, MoneyGram.
Ophthalmic Touch Screen Automatic Optical Coherence Tomography OCT Scanner Machine supplier