- Overview
- Recommended Products
Make your diagnose More accurate
· High-frequency generator deliver the power you need for all the typical applications in spine surgery, orthopedics,traumatology,urology and pain management.
· Unique design of large thermal capacity(>1000kJ) with advanced heat dissipation technology, allows for clear image seven for long or repeated procedures.
· High-resolution CCD camera with 1Kx1K image matrix, over4000 shades of gray, realizes more accurate diagnose.
· Advanced functions of Images optimization, strengthen module,real-time displaying the clear clinical images.
· Professional working station has more image post-processing functions such as the image W/L adjustment, region of interest balance, GAMMA correction,flip, noise reduction, smoothing,sharpening etc.
· Two monochrome 19" flat-screen monitors clearly visualize the smallest anatomical details.
Reduce the X-ray radiation to the minimum
· Short, sharp pulses for clear images and the radiation exposure for the operators and patients can be reduced to a minimum.
· Motorized iris collimator with multi-leaf, supports high accuracy for selected x-ray field size.
· Crosshair overlay corresponding with laser light, designed for easily checkpoint location before operation, avoiding unnecessary exposure.
· Professional remote controller for exposure, allows operators retreating to X-ray exposure.
· Professional storage system for single and continuous images, reducing the repeatability of the exposure.

|
HCX-70B |
HCX-70C | |
|---|---|---|
| High Frequency Inverter Power Supply | Output power: 12kW Inverter frequency: 60kHz | Output power: 16kW Inverter frequency: 60kHz |
| Automatic, Manual Continuous Fluoroscopy | Tube voltage:40kV~125kV continuous adjustment Tube current:0.3mA~4mA continuous adjustment | Tube voltage: 40kV~125kV continuous adjustment Tube current: 0.3mA~4mA continuous adjustment |
| Automatic, Manual Intensifying Fluoroscopy | Tube voltage:40kV~125kV continuous adjustment Tube current:0.3mA~8mA continuous adjustment | Tube voltage: 40kV~125kV continuous adjustment Tube current: 0.3mA~8mA continuous adjustment |
| Automatic, Manual Pulse Fluoroscopy | Tube voltage:40kV~125kV continuous adjustment Tube current:0.3mA~30mA continuous adjustment Pulse frequency:0.1–10 frame/s continuous adjustment | Tube voltage: 40kV~125kV continuous adjustment Tube current: 0.3mA~30mA continuous adjustment Pulse frequency: 0.1–10 frame/s continuous adjustment |
| DSI Digital Spot Film | 0.1–10 frame/s can be chosen freely | 0.1–10 frame/s can be chosen freely |
| Radiography Tube Voltage, mA | 40kV~125kV 160mA | 40kV~125kV 200mA |
| X-ray Tube Special For High Frequency | Rotary anode focus: 0.3/0.6 Anode thermal capacity: 212kJ | Rotary anode focus: 0.3/0.6 Anode thermal capacity: 212kJ |