- Faahfaahin
- Bixiyo Oo La Sameeyo
-Mudul: HDR50

Xulinta sistamka
HDR50 Sistam Digital High Frequency Radiography | |
Awood sare F teeqaadda H iigsan V oltage X -ray X x x jeneretaar |
YJO-IV |
X-ray T ube A ssembly |
Made-in-China |
Kuollimator |
YJA-VM |
Digital D etector |
Iray marka ah ee Ciiniga |
Koonfur Frame ee DR |
YJS-V |
Radiography T able |
YJS -V |
Computer iyo LCD |
DCSM1F/ML2002 |
Awood sare V oltage C able |
75kV (dherer: 8m) |
Grid (Marka: JPI) |
100cm iyo 180cm Made-in-Korea |
Xuruufka Sare, Xalka Sare ee X-ray ah
YJO- ⅳ leh konsolka shaqada | |
Awood |
AC380V ± 38V |
Xuruufta Tube Radiography |
40kV ~ 150kV |
Kuwoorinta Xalka Radiography |
10mA ~ 630mA |
T ime |
2ms ~ 6300ms |
Xaqiiqsiga Dhexeeya Loo Xushay |
380V: 0.5Ω |
Weydiimadda Tiyegista Loo Xushay |
50Hz/60Hz ± 1Hz |
Frekweensiiska isku cararaya |
≥300kHz |

Fokus |
0.6mm/1.2mm |
Xawaaraha Koronto |
2800rpm |
Woltajka Tube Peek |
150kV |
Foco kuleel |
20kw |
Fokus koonfur |
50kW |
Collimator M-38
Halaqa korontada |
Kol |
Awood |
24VAC |
Filtration dheer |
1.2mmAL |

Raadiyaya diijitaal Rayence
Goobta Kululka |
17 × 17 inchi |
Habka Gaaraan R xaqiiqda |
sana marka weyn ama lacag la'aan 3. 9lp/mm |
T otal P pixel M matrix |
3,328(h ) × 3,328(v ) |
Dhexeeya Pixel |
127 |
Sawirka P dib u eegis T ime |
yarlaha ka yar 2s |

DR Machine Frame YJS-V
Farsamada nolosha horizantiga ee leaba |
≥250mm |
Farsamada nolosha verticale ee leaba |
≥825mm |
Cayimaanka meesha (Dherer × Gaara × Jir) |
2100 × 825× 655mm |
Halaqa aasaasiga ah |
Yar iyo elektronik |
Ku jirta cuno |
Yar marka la yidhaahdo 250kg |
Kompuyuta iyo LCD DCSM1F/ML2002 CPU |
≥2.8GHz |
Xoggaalka |
≥4GB |
Qoraalka Diska |
≥500GB |
LCD Dibadda |
23 inchi |

Astaamaha Ugu Muhiimsan:
golaha Barashada 1 ee Tallaabta Sare
1.1 Wajibaadka: X-ray digitaalka radigography, x-ray filter radiography,
Bucky stand Radiography, ARP iyo AEC.
1.2 Halaqa la xisaabiyey: 50 kW
1.3 Khaasadda tube: 40kV~150kV
1.4 Daqiiqada tube: 10mA~630mA
1.5 Waqtiga: 2ms~10s
1.6 mAs: 0.1mAs~630mAs
1.7 Taajida shaqada: ≥400kHz
1.8 Fanelka barnaamijka: Ekranka ku tiilinta LCD
2 X-ray Tube
2.1 Siihan ugu weyn ee tubka: 150kV
2.2 Focus: Focus yahansan: 0.6mm; Focus weyn: 1.2mm
2.3 Gargaarka anode: focus yahansan 19kW, focus weyn 50kW
2.4 Kulankee shuqulta: 12°
2.5 Anode RPM: 2800rpm
2.6 Hela khaadhinta: 150kHU
3 Goobta Helida
3.1 GOS & Csl
3.2 Siyaasadda: 35×43cm (14×17 inch)
3.3 Pixel: 140μm
3.4 Matrixka Pixel: 2560×3072
3.5 Isku dulqaadashada A/D: 16Bit
4 Meesha Raadiyograafi
4.1 Siyaasadda: 2100mm×825mm×655mm (LxWxH)
4.2 Furfurda Hor-ta-fur: ≥250mm;
4.3 Furfurda Dhererka: ≥825mm;
4.4 Qaafka meesha la dhagaysta: Qaafka elektromagnatig, ku taal xadka ≥100N, leh guud in soo saarka, raac iyo fudud.
4.5 Iyada oo leh wejiga elektrik ama wejiga manual ee horumarinta mekaniiksi, waxaana leeyahay tijaabo xusid ah oo isku halligta kanal x-ray iyo kaashinka.
4.6 Gaarkheeda qaybta: ≥15"×18"; Dhererka aragga qaybta: f0=100cm; Xaaladda qaybta: r=10 :1; Tafatifta qaybta: N=103Lines/Inch
4.7 Kolummka Tube
4.7.1 Caymadda aamin iyo kaga cad
4.7.2 Isku dheelitirka kolummka: ≥±180°
4.7.3 Furfurda waddiyeed meesha la dhagaysta: ≥1575mm, ayaa loo qaadsho go'aamis kasta
4.7.4 Horumarinta tube sii keliya & hoose: 930mm±10mm, ayaa loo qaadsho go'aamis kasta
4.7.5 Isku dheelitirka tube: ≥±180°
4.7.6 Dhererka ugu sarreeya kaas oo ah focus tube ilaa filmka: ≥1200mm.
5 Bucky Stand
5.1 Fagaagga ku socota Sare & Hoos: ≥1200mm;
5.2 Dhererka ugu sarreeya, dhinaca hoose iyo markaas xarunta dabadda waa ≥1500 mm;
5.3 Habdhaha sare: 18×18"; Focuska habdhaha: f0=180cm; Xariijinta habdhaha: r=10 :1; Tafatuminna habdhaha: N=103Lines/Inch
6 Kollimator: Raax ah iyo fudud in la isticmaal, iyo saacidda raadiyograafiiga kooxkooda dhan waxay leedahay saacidda koox.
Si fiican koor
Maya. |
Magacyada Qaybooyinka |
QTY |
|
Faallooyinka |
1 |
Golaha High Frequency |
1 Pc |
|
|
2 |
Borqaad Tahay |
1 Pc |
|
|
3 |
X-Ray Tube |
1 Set |
|
|
4 |
Kuollimator |
1 Pc |
|
|
5 |
Detektorrada Flat Panel iyadoo la isticmaalayo Software |
1 Set |
14*17 |
|
6 |
Bucky Stand |
1 Pc |
|
|
7 |
Meesha Raadiyograafi |
1 Pc |
|
|
8 |
Koompiyutaar (Computer) |
1 Set |
-- |
|
9 |
Grid |
2 qof |
18"×18" |
JPI |
10 |
Kabelka Tension-Weyn |
1 pair |
75kV |
|